LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> GT1-FOP08 I/O points: 8 OMRON GT1-FOP08 Relay Output Units

GT1-FOP08 I/O points: 8 OMRON GT1-FOP08 Relay Output Units

Brand: OMRON
Name: Relay Output Units
Model: GT1-FOP08
I/O classification: SSR.
I/O points: 8.
I/O connections: M3 terminal block.
Power supply voltage: 24 VDC.
I/O specification: --.
Relay Output Unit Compatible with MULTIPLE I/O TERMINAL.
8- and 16-point relay output models are available.
Equipped with 8-point SSRs.
DIN track mounting.

I/O classification: Output.
Internal I/O circuit common: NPN (- common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals OMRON GT1-FOP08 GT1-FOP08
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
classification: Relay output.
I/O points: 8 points.
Rated voltage: 24 VDC.
Relay coil rating: 24 VDC.
Applicable relay: G6D-1A OMRON GT1-FOP08.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W x H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models.
DIN track mounting and screw mounting are available. Name: Slice I/O Units; Counter Units.
Specifications: Counter inputs: 1,
External outputs: 1 NPN.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON GT1-FOP08.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON Relay Output Units.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON Relay Output Units. Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal) OMRON Relay Output Units.
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminnal is provided for,
each connector GT1-FOP08.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
swwitch and with tool software OMRON GT1-FOP08.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.


...More relevant models >>>>