Rotary device with a display unit, which is always capable of reading from the front.
There is no need to adjust the time of sunrise and sunset in support of daylight saving time when the seasons change.
5 modes of operation. (4 kinds of Sunshine Action)
With automatic reset function, to prevent misuse.
Supply voltage: 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: DPDT.
Long-time range model(0.1 min to 10 h).
Miniature Timer with Multiple Time Ranges,
and Multiple Operating Modes.
UL listed when used with a Push-In Plus Terminal Block Socket.
Conforms to CSA, CE Marking, LR, and CCC OMRON H4KV-DSA-R.
Black design with power supply terminals on top and contact output,
terminals on bottom
H4KV-DSA-R
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock. Timer input: AC/DC multi-voltage input(24 to 240 VAC/VDC).
Display: 7-segment LCD.
Time range: 999999.9h ←→ 3999d23.9h(switchable); Black body.
Seven digits, time range 0 to 3999d23 OMRON H4KV-DSA-R. 9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Power ratings: 30 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 VDC.
Output current: 1.3 A.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
Easy programming is available using the LCD and operation,
buttons OMRON H4KV-DSA-R. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions.
Expansion is easy with Expansion I/O Units, allowing up to 44,
I/O points. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series OMRON Sunshine time switch.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±15 s,
max OMRON Sunshine time switch. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC. Type of input: AC current input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with OMRON Sunshine time switch.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped wwith H4KV-DSA-R.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub preessure gauge for monitoring the operation trend OMRON H4KV-DSA-R.
External event input can be applied to a variety of measurement and identification situations.
Device