LK Automation Limited
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Distributed power supply >> K2ZC-K2FU-N OMRON K2ZC-K2FU-N Waste heat generation system improve the comprehensive energy efficiency and the use of natural, Composite relay for the connection of a distributed power supply system

K2ZC-K2FU-N OMRON K2ZC-K2FU-N Waste heat generation system improve the comprehensive energy efficiency and the use of natural, Composite relay for the connection of a distributed power supply system

Brand: OMRON
Name: Composite relay for the connection of a distributed power supply system
Model: K2ZC-K2FU-N
Model: UFR (95L).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring.

Cable core number: 4.
Cable lead direction: straight line type.
Cable length: 10m.
Save time, save maintenance cost,
With a waterproof connector environment and strong tolerance of FA.
For IP67, the FA 94V-0 connector small special flammability.
The wiring system makes the device more maintainable connector,
And reduce the downtime of equipment OMRON K2ZC-K2FU-N.
Introduction of connector and modular connector with cable K2ZC-K2FU-N
A modular connector crimping type, welding type, screw connection type 3.
With the cable connector is obtained UL certification of products.
According to IEC61076-2-101 (IEC60947-5-2), NECA4202. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC OMRON K2ZC-K2FU-N.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 15 V.
Output current: 2.4 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22 OMRON K2ZC-K2FU-N. 2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.) OMRON Composite relay for the connection of a distributed power supply system. Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3) OMRON Composite relay for the connection of a distributed power supply system.
Output voltage: 24 V.
Output current: 5 A.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning OMRON Composite relay for the connection of a distributed power supply system.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards K2ZC-K2FU-N.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) OMRON K2ZC-K2FU-N.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)


...More relevant models >>>>