Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse is 25kHz, increase or decrease of pulse is 30kHz
Operating modes: Flicker OFF start.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC.
0.05 s to 300 h models: 8-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
time settings are possible OMRON K3HB-CNB-CPAC21 AC/DC24V
K3HB-CNB-CPAC21 AC/DC24V
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range.
Length, when panel-mounted with a Socket, of 80 mm or less OMRON K3HB-CNB-CPAC21 AC/DC24V.
11-pin and 8-pin models are available. Timer input: No-voltage input.
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h59.9min(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Supply voltage: 12 to 24 VDC.
6-digit total counter: Black.
DIN 48 x 24-mm Total Counter/Time Counter,
with Easy-to-read Displays and Water and,
Oil Resistance Equivalent to IP66 OMRON K3HB-CNB-CPAC21 AC/DC24V.
High-visibility, negative transmissive LCD display with 8.5-mmhigh characters and, built-in red LED backlight at low power.
consumption.
IP66 with oil resistance and NEMA 4 protection achieved by,
unifying the front with the case and by using oil-resistant parts,
and materials OMRON Cumulative / increase / decrease pulse meter OMRON Cumulative / increase / decrease pulse meter.
Compact (80 mm) body.
Just change a switch setting for either an NPN or PNP input.
Supports both external resetting and manual resetting.
Finger-protection terminal block cover prevents electrical shock,
and conforms to VDE0106, Part 100.
Certified for UL and CSA safety standards.
Complies with EMC standards (EN 61326) and CE Marking OMRON Cumulative / increase / decrease pulse meter. Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
BCD+ transistor: -- NPN open coollector (5 bit output +HH, H, PASS, L, LL) K3HB-CNB-CPAC21 AC/DC24V.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can swiitch the green / Red 2 kinds of color display OMRON K3HB-CNB-CPAC21 AC/DC24V.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signal, the highest