LK Automation Limited
Home >> Products >> OMRON >> Control equipments >> Digital panel table >> Pulse input >> K3HB-PPB-FLK1AT11 AC100-240 Measurement of 2 points through the speed, time, or cycle of the digital time interval table OMRON K3HB-PPB-FLK1AT11 AC100-240

K3HB-PPB-FLK1AT11 AC100-240 Measurement of 2 points through the speed, time, or cycle of the digital time interval table OMRON K3HB-PPB-FLK1AT11 AC100-240

Brand: OMRON
Name: Time interval table
Model: K3HB-PPB-FLK1AT11 AC100-240
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable

Type: instantaneous contact.
Terminal configuration type: special terminal configuration.
Pin type: 8 pin.
Action mode / reset mode: time limit action / auto reset.
Output mode: contact output.
Installation method: embedded installation / front mounting.
1 units can be in 0.5 seconds to 120 seconds, select the 4 time range OMRON K3HB-PPB-FLK1AT11 AC100-240.
Achieved UL, CSA, NK, LR certification, in compliance with EN61812-1 K3HB-PPB-FLK1AT11 AC100-240
Conform to the CE mark, CCC. Type: H7CX-A Series.
Classification: Preset counter.
Configuration: 1-stage preset counter; Total and preset counter.
External connections: 11-pin socket.
Settings: 1-stage.
Display digit: 6 digits.
Outputs: Transistor output (SPST).
Power supply voltage: 12 to 24 VDC/24 VAC OMRON K3HB-PPB-FLK1AT11 AC100-240.
Ultra-compact Counter Provides More,
Complete Functionality.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals).
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange.
Safety and Reliability.
New set value limit and counter functions have been added OMRON K3HB-PPB-FLK1AT11 AC100-240.
Other Features.
Front Panel can be changed to white or light gray.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series OMRON Time interval table. Type of input: AC current input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with OMRON Time interval table.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table OMRON Time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemInput type: DC voltage input type.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-PPB-FLK1AT11 AC100-240.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub ppressure gauge for monitoring the operation trend OMRON K3HB-PPB-FLK1AT11 AC100-240.
External event input can be applied to a variety of measurement and identification situations.
Devi