Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
DIN 48 × 48-mm Star-delta Timer.
A wide star-time range (up to 120 seconds) and star-delta.
transfer time range (up to 1 seconds). Unit: CPU Units.
Name: Economy type (Expansion I/O Units cannot be connected) OMRON K3HB-VLC-FLK1BT11 AC100-240.
No. of I/O points: 10.
LCD display: Yes.
Power supply voltage: 100 to 240 VAC.
Inputs: 6, 100 to 240 VAC.
Outputs: 4, Relays.
Buttons, calendar, and clock: Yes
K3HB-VLC-FLK1BT11 AC100-240
Analog input: NO.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
Easy programming is available using the LCD and operation,
buttons OMRON K3HB-VLC-FLK1BT11 AC100-240. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions.
Expansion is easy with Expansion I/O Units, allowing up to 44,
I/O points. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series.
Improved Weekly Timers (See note 1 OMRON K3HB-VLC-FLK1BT11 AC100-240. ).
Increased timing accuracy with a monthly deviation of ±15 s,
max. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC. Input type: high speed response type OMRON Load sensor mV instrument.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors OMRON Load sensor.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type OMRON Load sensor.
The depth (panel below) is only 95mm superOperating modes: Flicker OFF start.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC.
0.05 s to 300 h models: 8-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFFF- or ON,
time settings are possible K3HB-VLC-FLK1BT11 AC100-240.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range mV instrument.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available.