LK Automation Limited
Home >> Products >> OMRON >> Control equipments >> Digital panel table >> Voltage / current input >> K3HB-XAA-BCD1 AC100-240 OMRON Voltage and current panel meter OMRON K3HB-XAA-BCD1 AC100-240

K3HB-XAA-BCD1 AC100-240 OMRON Voltage and current panel meter OMRON K3HB-XAA-BCD1 AC100-240

Brand: OMRON
Name: Voltage and current panel meter
Model: K3HB-XAA-BCD1 AC100-240
Type of input: AC current input.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
D

Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A-2: Power ON Delay I, b: Repeat cycle 1,
E: Interval, Z: ON/OFF-duty-adjustable flicker, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1 OMRON K3HB-XAA-BCD1 AC100-240 K3HB-XAA-BCD1 AC100-240
External connections: 8-pin socket.
Input: None.
Output: Contact output (time-limit SPDT + instantaneous SPDT),
Models with instantaneous contact outputs.
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Operating method: Incrementing and decrementing (selectable with DIP switch) OMRON K3HB-XAA-BCD1 AC100-240.
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable) OMRON K3HB-XAA-BCD1 AC100-240.
Set value read: Continuous mode.
Memory backup: Yes/No (Selectable using DIP switch).
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 2 stages.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches OMRON Voltage and current panel meter.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available OMRON Voltage and current panel meter.
Total Counter models are also Available.
Complies with UL and CSA Marking. Supply voltage: 24 to 230 VAC (50/60Hz)/24 to 48 VDC.
Control output: Contact output: SPDT (time-limit output SPDT).
Input type: Voltage input.
Operating mode(see note): Eight multi-modes: A, B, B2, C, D, E, G, J OMRON Voltage and current panel meter.
Model: Screw terminal type.
Eight operating modes (H3DS-M) and four operating modes,
(H3DS-S) cover a wide range of applications.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status respectively. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: DeviceNet; -; DeviceNet.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision meaasurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XAA-BCD1 AC100-240.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations OMRON K3HB-XAA-BCD1 AC100-240.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard for recognition


...More relevant models >>>>