Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A-2: Power ON Delay I, b: Repeat cycle 1,
E: Interval, Z: ON/OFF-duty-adjustable flicker, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1 OMRON K3HB-XAA-BCD1 AC100-240
K3HB-XAA-BCD1 AC100-240
External connections: 8-pin socket.
Input: None.
Output: Contact output (time-limit SPDT + instantaneous SPDT),
Models with instantaneous contact outputs.
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Operating method: Incrementing and decrementing (selectable with DIP switch) OMRON K3HB-XAA-BCD1 AC100-240.
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable) OMRON K3HB-XAA-BCD1 AC100-240.
Set value read: Continuous mode.
Memory backup: Yes/No (Selectable using DIP switch).
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 2 stages.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches OMRON Voltage and current panel meter.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available OMRON Voltage and current panel meter.
Total Counter models are also Available.
Complies with UL and CSA Marking. Supply voltage: 24 to 230 VAC (50/60Hz)/24 to 48 VDC.
Control output: Contact output: SPDT (time-limit output SPDT).
Input type: Voltage input.
Operating mode(see note): Eight multi-modes: A, B, B2, C, D, E, G, J OMRON Voltage and current panel meter.
Model: Screw terminal type.
Eight operating modes (H3DS-M) and four operating modes,
(H3DS-S) cover a wide range of applications.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status respectively. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: DeviceNet; -; DeviceNet.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision meaasurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XAA-BCD1 AC100-240.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations OMRON K3HB-XAA-BCD1 AC100-240.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard for recognition