The built-in I/O function (Location: 1 axis) of the pulse output is converted to a differential drive output.
Can be used as a screw relay terminal. Negative common end useConverts the built-in I/O function to the screw terminal.Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 40 s/2ch.
Resolution: 1/32000.
Status of connected devices by means of alarm monitoring MITSUBISHI FA-PT1LBD.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm
FA-PT1LBD
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement MITSUBISHI FA-PT1LBD.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period MITSUBISHI FA-PT1LBD.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. Number of input channels: 8ch.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function MITSUBISHI Positioning module.
Shift the set value to (shift to) the function of the digital output value MITSUBISHI Positioning module.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal whhich is outside the range of the set range MITSUBISHI Positioning module FA-PT1LBD.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter rannge extension
Range of scalable input range MITSUBISHI FA-PT1LBD.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.