LK Automation Limited
Home >> Products >> MITSUBISHI >> Inverter >> FR-F800 series inverter >> FR-F820 inverter 3 phase 200V >> MM-EFS30K1M4 IPM motor MITSUBISHI MM-EFS30K1M4 IPM motor MM-EFS series can not be used to run the power frequency power 

MM-EFS30K1M4 IPM motor MITSUBISHI MM-EFS30K1M4 IPM motor MM-EFS series can not be used to run the power frequency power 

Brand: MITSUBISHI
Name: IPM motor
Model: MM-EFS30K1M4
Superior high efficiency IPM motor.
Output power: 30kw.
Rated speed: 1500r/min.
Voltage level: 400V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time.

MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 45kw.
SLD converter rated current: 233A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on MITSUBISHI MM-EFS30K1M4 MM-EFS30K1M4
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units MITSUBISHI MM-EFS30K1M4.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Power: 3.7kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor MITSUBISHI MM-EFS30K1M4. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI IPM motor. ) Power: 55kw.
Voltage: 200V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor MITSUBISHI IPM motor.
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available.
Please select according to the required braking torque. MITSUBISHI inverter series: FR-A820 MITSUBISHI IPM motor.
Voltage level: three phase 200V.
Power: 11kw.
SLD converter rated current: 63A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with thee FR-A700 series, to reduce the volume of equipment) MM-EFS30K1M4.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network MITSUBISHI MM-EFS30K1M4.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.


...More relevant models >>>>