LK Automation Limited
Home >> Products >> OMRON >> CJ2/CJ1 PLC >> CJ2M/CJ2H CPU >> OMRON CJ2M-CPU15 Programmable Controllers OMRON CJ2M-CPU15

OMRON CJ2M-CPU15 Programmable Controllers OMRON CJ2M-CPU15

Brand: OMRON
Name: Programmable Controllers
Model: CJ2M-CPU15
Product name: CJ2M CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2, 560 points/40 Units(3 ExpansionRacks max. );Programcapacity,
60K steps;Data memorycapacity, 160K words,
(DM: 32K words, EM: 32K words ×4 banks);
LD nstruction execution time, 0. 04 μs;
EtherNet/IP function: --;
Option board slot: --.
Current consumption (A): 5V, 0. 7(See note. );24V, --.
Standards: UC1, N, L, CE.
CJ2M for basic machine automation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU.

Product name: CJ1M CPU Units; built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
160 points/10 Units (No Expansion Rack); Program capacity,
5K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0.1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs OMRON CJ2M-CPU15.
Current consumption: 5v, 0 CJ2M-CPU1564A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Unit type: CJ1 CPU Bus Unit.
Product Name: Controller Link Unit.
Specifications:Communications cable,
Wired shielded wisted-pair cable ;
Communications type,
Data links and message service;
Duplex support, No;
Max OMRON CJ2M-CPU15. Units mountable per CPU Unit, 8;
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.35A; 24V,--.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an FA,
network that can send and receive,
large amounts of data easily,
and at high speed.
The Controller Link supports data,
links that enable sharing,
data between PLCs and computers,
and a message service that enables,
sending and receiving data whenever required OMRON CJ2M-CPU15.
Systems can be flexibly built by using Repeater,
Units to enable T-branches, long-distance wiring,
and converting part of the network to optical cable OMRON Programmable Controllers. Type: CS Special I/O Unit.
Connected ID System: V680 Series; 2 Heads.
External power supply: 24VDC OMRON Programmable Controllers.
No. of unit numbers used: 2 unit number.
Current consumption: 5V, 0.32A;
24V, --; External, 0.36A.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC OMRON Programmable Controllers.
Allows batch transfer of data up to 32 kbytes. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 4 to 20mA;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block.
External power supplyy: 24 VDC +10% -15%, 170mA max CJ2M-CPU15.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.17*3.
Standards: UC1, N, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data OMRON CJ2M-CPU15.
Analog Output Units for converting binary ,
data into analog output signals.


...More relevant models >>>>