16 points.
I/O connections: MIL connector.
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).
Short/disconnection detection: Supported.
Specifications: I/O, PNP (input: - common, output: + common), 16 inputs/16 outputs.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring OMRON DRT2-ID16ML-1.
Screw-less structure eliminates tightening work
DRT2-ID16ML-1
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Short/disconnection detection: Supported.
Specifications: Outputs, NPN (- common), 32 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector OMRON DRT2-ID16ML-1.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Specifications: Outputs; PNP (+ common); 16 points.
I/O connections: MIL connector OMRON DRT2-ID16ML-1.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H) OMRON MIL Connector Terminals with Transistors. Name: Analog I/O Slave Units,
(Numerical indicator type)
MIL Connector Type.
Specifications: Analog inputs OMRON MIL Connector Terminals with Transistors.
(Channel Insulation); 2 inputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON MIL Connector Terminals with Transistors.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit: Terminal block model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 16.
I/O connections: M3 termminal board DRT2-ID16ML-1.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The ciircuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires OMRON DRT2-ID16ML-1.
DIN track mounting.