Specifications: Outputs, PNP (+ common), 8 points.
I/O connections: Sensor I/O connector.
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
operation status monitoring and effective maintenance.
construction. (IP67)
connection with hydraulic valve devices.
Name: Screw Terminal Block with SSR Outputs.
Specifications: Outputs;
16 outputs; SSR.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON DRT2-OD08CL-1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
DRT2-OD08CL-1
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Slice I/O Units; Counter Units.
Specifications: Counter inputs: 1,
External outputs: 1 PNP OMRON DRT2-OD08CL-1.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON DRT2-OD08CL-1.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit: Terminal block model.
I/O classification: Digital input.
Internal I/O common: NPN (+ common).
I/O points: 16.
I/O connections: M3 terminal board.
Power supplyvoltage: 24 VDC OMRON Environment-resistive Terminals with Transistors .
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available OMRON Environment-resistive Terminals with Transistors .
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. Input capacity: 32 points.
Internal I/O common: PNP OMRON Environment-resistive Terminals with Transistors .
ON voltage: 15 VDC min. (between each in,
put terminal and the G terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the G terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 32 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 230 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector DRT2-OD08CL-1.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswitch and with tool software OMRON DRT2-OD08CL-1.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.