Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve.
Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - OMRON E5EC-CQ4DSM-010.
Event input points: -.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products
E5EC-CQ4DSM-010
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms OMRON E5EC-CQ4DSM-010.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultTerminal type: Exposed-lead Models OMRON E5EC-CQ4DSM-010.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard OMRON Digital temperature controller.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON Digital temperature controller.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON Digital temperature controller. Control output 1: Voltage output.
Control output 2: --.
Auxiliary output: Three.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operaation E5EC-CQ4DSM-010.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of oonly 60 mm OMRON E5EC-CQ4DSM-010.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.