Brand: OMRON
Name: Basic-type Digital Temperature Controller
Model: E5GN-Q101TD-FLK
Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.

Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: 1 loop for standard control,
Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Current and Current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity OMRON E5GN-Q101TD-FLK E5GN-Q101TD-FLK
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller OMRON E5GN-Q101TD-FLK.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming OMRON E5GN-Q101TD-FLK. Control output: Voltage output.
Auxiliary output: Two.
Communications: --.
Heater burnot: Detection for Single-phase heater.
Event inputs: One.
Power supply voltage: 100 to 240 VAC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs OMRON Basic-type Digital Temperature Controller.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series OMRON Basic-type Digital Temperature Controller.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications OMRON Basic-type Digital Temperature Controller.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Fuurther performance improvement E5GN-Q101TD-FLK.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV OMRON E5GN-Q101TD-FLK.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.


...More relevant models >>>>