Coil contact between the Part68 FCC standard. (1500V, 10 * 160 s)
Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, 3PST-NO/SPST-NC; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations) OMRON G5V-1 DC6.
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations)
G5V-1 DC6
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block OMRON G5V-1 DC6.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications OMRON G5V-1 DC6. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations OMRON Power relay.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations OMRON Power relay.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation OMRON Power relay.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 25 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliannt G5V-1 DC6.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIIN Track mounting types mount to DIN Track OMRON G5V-1 DC6.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).