Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA OMRON K3HB-VLC-CPBC11 AC/DC24V.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors
K3HB-VLC-CPBC11 AC/DC24V
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type OMRON K3HB-VLC-CPBC11 AC/DC24V.
The depth (panel below) is only 95mm superOperating modes: Power OFF Delay.
Supply voltage: 24 to 48 VAC/DC.
Control output: Contact output: SPDT.
H3DK-H: L Series (time range: 1.0 to 120 s).
Set two time ranges with each Timer, from 0.1 to 12 seconds for,
the S Series and from 1 OMRON K3HB-VLC-CPBC11 AC/DC24V. 0 to 120 seconds for the L Series. Rated supply voltage: 100 to 240 VAC.
Resetting system (See note.): Electric resetting.
Control output: DPDT contact output,
(Time-limit output SPDT and instantaneous output SPDT).
Time range: 0.2 s to 12 h (12 s, 120 s, 12 min, 120 min, 12 h) OMRON Load sensor.
Large Setting Dial and Moving Pointers Ideal,
for Easy Operation and Monitoring.
Incorporating an easy-to-see large setting dial with moving pointers.
Wide time-setting range of 0.2 s to 60 h.
(available through three time-range model types).
Wide AC power supply range (100 to 240 VAC) OMRON Load sensor.
IP65 watertight and dust-tight front panel.
Approved by UL and CSA.
Conforms to EN61812-1 and IEC60664-1.
4 kV for Low Voltage, and EMC Directives.
Conforms to EMC standards.
Six-language instruction manual provided.
Programmable contact enables the building of a self-holding,
relay circuit as well as built-in instantaneous contact OMRON Load sensor. (-NS).
Memory retention (--NSR) mV instrument.
Finger protection terminal block.
Enables easy sequence checks through instantaneous outputs.
for a zero set value at any time range. Type: H5CZ.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s,
1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min, 1 to 9999 min,
1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 8-pin socket.
Inputs: Signal, Reset (NPN inputs).
Outputs: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and iinput circuits are isolated for safety and reliability K3HB-VLC-CPBC11 AC/DC24V.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer oor,
the load mV instrument.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.