LK Automation Limited
Home >> Products >> OMRON >> Energy saving/Environmental protection testing equipment >> Electricity monitoring >> OMRON KM50-E1-FLK Smart Power Monitor OMRON KM50-E1-FLK

OMRON KM50-E1-FLK Smart Power Monitor OMRON KM50-E1-FLK

Brand: OMRON
Name: Smart Power Monitor
Model: KM50-E1-FLK
Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model.)
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.

The temperature, humidity and differential pressure of the cleaning chamber and the simple cleaning room by using PC,
Power consumption and other manufacturing environment.
Implement unified management software.
Centralized management of environmental information in the production site.
Real time analysis of measurement data OMRON KM50-E1-FLK.
Installation site and measurement conditions can be understood through the map KM50-E1-FLK
Can only be converted to the required data format Excel. Easy temperature and humidity control with an SD Card. Sensor that can be connected: Thermo-Humidity Sensor Head (ZN-THS1__-S).
Display: LCD 7-segment 5-digit 2-step display,
auxiliary information indicator display.
Measurement interval: 10 s, 20 s, 30 s, 1 min, 2 min,
5 min, 10 min, 20 min, 30 min, 1 h OMRON KM50-E1-FLK.
Calculation function: Instantaneous value, maximum value,
minimum value, average value.
Operating mode: Normal mode, sleep mode.
Recording mode: Continue, ring.
Alarm signal output: Output to photocoupler (External power supply: 12 to 24 VDC,
Load current: Max. 45 mA) Alarm hold setting is possible.
Internal storage device: Internal memory: Approx OMRON KM50-E1-FLK. 8,500 data items.
External storage device: SD card (to save measured values and to save/read set, values),Recommended SD card: HMC-SD291 (manufactured by OMRON).
Power supply voltage: DC input: 24 VDC±10%, Battery: 2 AAA batteries OMRON Smart Power Monitor.
Battery life: Approx. 1 year∗6 (sleep mode, measurement interval of 10 minutes, with 2 AAA nickel metal hydride batteries, with SD card not inserted) OMRON Smart Power Monitor.
Operating temperature range: 0 to 60°C.
Operating humidity range: 20 to 85% (no condensation).
Weight (packaged): Approx. 500 g.
Accessories: Instruction Sheet, Startup Guide CD-ROM∗7,
Alarm output connector∗8, DC cable (straight type).
Easy temperature and humidity control with an SD Card OMRON Smart Power Monitor. Type: related equipment (sold separately); split type current transformer (CT).
Rated primary side current: 100A.
Rated two secondary current: 1A.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipment, the measuremennt of the initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency KM50-E1-FLK.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network OMRON KM50-E1-FLK.
Wide 45mm miniaturization, simple set to the DIN guide.


...More relevant models >>>>