LK Automation Limited
Home >> Products >> OMRON >> Power/other peripheral devices >> Axial fan >> OMRON R87F-A4A15HP Permitted voltage fluctuation range: 85% to 110% rated voltage OMRON R87F-A4A15HP

OMRON R87F-A4A15HP Permitted voltage fluctuation range: 85% to 110% rated voltage OMRON R87F-A4A15HP

Brand: OMRON
Name: AC Axial Fans
Model: R87F-A4A15HP
Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.210 A; 60 Hz, 0.180 A .
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2450 r/min; 60 Hz, 2700 r/min.
Maximum flow rate: 50 Hz, 2.2 m3/min; 60 Hz, 2.5 m3/min.
Maximum static pressure: 50 Hz, 63.7 Pa; 60 Hz, 63.7 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 42 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Control power supply voltage: 100/110 VAC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) OMRON R87F-A4A15HP.
Detect three-phase AC current for under and/or overcur,
rent using current converter R87F-A4A15HP
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) OMRON R87F-A4A15HP.
LED operation indicator.
UL/CSA approval (SDV-F@). Model: PY (back-mounting), page 15, Solder terminals.
Number of pins: 8 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available OMRON R87F-A4A15HP.
New screwless models available. Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal OMRON AC Axial Fans.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out OMRON AC Axial Fans.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Appearance: insert type OMRON AC Axial Fans.
Control supply voltage: DC24V.
Action elements: overload detection.
Action characteristic: anti time limit action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti time limit characteristics, lock timee, instantaneous action, etc R87F-A4A15HP. , are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT orr the relay part is not needed, and the use is simple OMRON R87F-A4A15HP.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple.


...More relevant models >>>>
Related model