LK Automation Limited
Home >> Products >> MITSUBISHI >> R series PLC >> R series analog module >> R60DA4 output module Input impedance: 1M MITSUBISHI R60DA4

R60DA4 output module Input impedance: 1M MITSUBISHI R60DA4

Brand: MITSUBISHI
Name: Analog output module
Model: R60DA4
Analog output channel number: 4CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Conversion speed: 80 s/CH.
Channel to channel insulation
Output short circuit protection: have.
External power supply: DC24.
External wiring connection mode: 18 point screw terminal.
Voltage output
Digital input value: 32000 ~ 32000.
Analog output voltage: DC - 10 - 10V.
Current output
Digital input value: 0 ~ 32000.
Analog output current: DC0 ~ 20mA.
The analog output module is the interface of analog signal to the external output through the programmable controller.
Can choose voltage output, current output, voltage / current mixed output type for a variety of purposes of the module.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the analog waveform, so the production line control, such as repetitive control,
Without using a special program to create the waveform, can reduce the programming time.

Output points: 64 points.
Output form: Transistor (drain type) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.2A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat).
External wiring connection: 40 pin connector two MITSUBISHI R60DA4.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type R60DA4
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point MITSUBISHI R60DA4.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. Capacity: 2MB.Analog input channel number: 4CH.
Available thermocouple: -.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s MITSUBISHI R60DA4.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range.
Sensor input when the action: according to the scale of the processing MITSUBISHI output module.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection mode: 18 point screw terminal MITSUBISHI output module.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater MITSUBISHI output module.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.
By cooperating with the time of arrival of a number of loops, the average temperature is controlled.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermal expansion. Can be divided into 16 groups,, with its heating up to the time,
Reduce the overall system in heating up the waste of energy R60DA4.
Peak current suppression function between modules
By the time staggered output transistor, suppressing peak current.
The power supply ccapacity of the equipment can be reduced by setting a larger channel and a smaller channel of the heater in the same set MITSUBISHI R60DA4.
Can be divided into 5 groups.


...More relevant models >>>>