Home >> Products >> OMRON >> Power/other peripheral devices >> Axial fan >> R87B-TA1A15HPFR3 OMRON R87B-TA1A15HPFR3 Maximum flow rate: 50 Hz, 35 m3/min 60 Hz, 40 m3/min Box Fan

R87B-TA1A15HPFR3 OMRON R87B-TA1A15HPFR3 Maximum flow rate: 50 Hz, 35 m3/min 60 Hz, 40 m3/min Box Fan

Brand: OMRON
Name: Box Fan
Model: R87B-TA1A15HPFR3
Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 3.5 m3/min; 60 Hz, 4.0 m3/min.
Maximum static pressure: 50 Hz, 68 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 50 dB; 60 Hz, 53 dB.
Weight: Approx. 3410 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.

Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 200 ~ 240VAC.
Rated power: 15W.
Output voltage: 24VDC.
Output current: 0.7A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market OMRON R87B-TA1A15HPFR3.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time R87B-TA1A15HPFR3 Cable Specifications: Fire-retardant, Robot cable,
(E2E models with conventional connector pin).
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0 OMRON R87B-TA1A15HPFR3. 5 mm.
Cable length: 5 m.
DC.
Minimum order: 5.
UL-listed: --.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available OMRON R87B-TA1A15HPFR3.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202 OMRON Box Fan. Cable length L: A, 15.0 m; B, 14.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch OMRON Box Fan. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models OMRON Box Fan.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standdards R87B-TA1A15HPFR3.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) OMRON R87B-TA1A15HPFR3.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)


...More relevant models >>>>