Brand: OMRON
Name: AC Axial Fans
Model: R87F-A1A93HP
Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.150 A; 60 Hz, 0.130 A .
Rated input: 50 Hz, 13 W ; 60 Hz, 11 W .
Rated rotational speed: 50 Hz, 2550 r/min; 60 Hz, 3050 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 49.0 Pa; 60 Hz, 68.6 Pa.
Noise: 50 Hz, 33 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/RJ45) .
Cable length: 0.5 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Power ratings: 60 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V OMRON R87F-A1A93HP.
Output current: 2.5 A.
Alarm output *2: --.
UL Class 2 Output standards: Yes R87F-A1A93HP
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor OMRON R87F-A1A93HP.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Cable: With cable.
Connector: Connectors on both cable ends.
Cable length: 3 m OMRON R87F-A1A93HP.
Minimum order: 5.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock OMRON AC Axial Fans.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned OMRON AC Axial Fans.
Connectors with Cables are UL approved. Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.5 .
Cable sheath material: PUR.
Cable color: Green.
Cable length: 20 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Type: Cable with Connectors on Both Ends (RJ45/RJ45) OMRON AC Axial Fans.
Category: Cat.5 .
Cable sheath material: PUR.
Cable color: Green.
Cable length: 3 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Control power supply voltage: 200/220 VAC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Avaiilable in 7 supply voltage configurations R87F-A1A93HP.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection OMRON R87F-A1A93HP.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).