Brand: OMRON
Name: AC Axial Fans
Model: R87F-A6A83L
Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.028 A; 60 Hz, 0.024 A .
Rated input: 50 Hz, 5 W ; 60 Hz, 4 W .
Rated rotational speed: 50 Hz, 1900 r/min; 60 Hz, 2100 r/min.
Maximum flow rate: 50 Hz, 0.4 m3/min; 60 Hz, 0.5 m3/min.
Maximum static pressure: 50 Hz, 19.5 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 28 dB; 60 Hz, 30 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element OMRON R87F-A6A83L.
Burnout Detector compatible with a,
wide-range of heater control methods R87F-A6A83L
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance OMRON R87F-A6A83L.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Detected voltage: AC.
Compact, Economical Plug-in Type Voltage.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication OMRON R87F-A6A83L.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal OMRON AC Axial Fans.
Wide voltage setting range with fine setting capability. Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.6a .
Cable sheath material: LSZH OMRON AC Axial Fans.
Cable color: Green.
Cable length: 1 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Power rating: 25 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 15 V VDC.
Output current: 1 OMRON AC Axial Fans. 7 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year wwarranty R87F-A6A83L.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved foor UL (all models) and CCC (15 to 150-W models) OMRON R87F-A6A83L.
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.


...More relevant models >>>>
Related model