Brand: MITSUBISHI
Name: IE Field CC-Link network module
Model: RJ71GF11-T2
1Gbps, master / local station.
IE Field CC-Link network is a kind of field network based on Gigabit Ethernet,
Integrated control of the controller, I/O control, safety control, motion control, can carry out a full range of control.
According to the production line, equipment, equipment layout, the star, linear and ring topology of flexible wiring.
Building a flexible network
Star topology
Star connection is carried out among the modules by using switching hubs.
When using star topology, you can easily add from the station.
Linear topology
Between the modules to carry out a linear connection.
Distribution cost can be reduced.
Ring topology
Ring connection in between each module.
Part of the anomaly occurs from the station, can be through the ring back function,
Use only normal station to continue data link.
Support IE Field CC-Link network synchronous communication function
According to the synchronization period specified by the master station, the control period of the slave station is synchronized by the IE Field CC-Link network.
According to this, the action time of the station can be synchronized with other slave stations which are connected on the same network.

Output points: 16 points.
Output form: relay output.
Rated open and close voltage, current: DC24V/2A, AC240V/2A.
Rated load voltage.
Max load current: -.
Response time: 12ms.
Common way: 16 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 18 point screw terminal MITSUBISHI RJ71GF11-T2.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type RJ71GF11-T2
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point MITSUBISHI RJ71GF11-T2.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. Analog input channel number: 4CH.
Available thermocouple: -.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s MITSUBISHI RJ71GF11-T2.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: none MITSUBISHI Temperature control module.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control MITSUBISHI Temperature control module.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater MITSUBISHI Temperature control module.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.
Temperature rising funnction between modules
By cooperating with the time of arrival of a number of loops, the average temperature is controlled RJ71GF11-T2.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomeenon of thermal expansion MITSUBISHI RJ71GF11-T2. Can be divided into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy.