Brand: OMRON
Name: Power failure detector
Model: S87A-11N
Type: 1 output.
Input power: 100/110/120V AC.
Detection, output form: voltage drop, power failure.
Power supply (commercial AC power supply) power cut detector for monitoring and control device.
Instantaneous detection voltage drop, power failure, instantaneous power failure.
Small, easy to install DIN guide rail mounting type.
Input voltage is divided into AC100V, AC200V two specifications.

Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element OMRON S87A-11N.
Burnout Detector compatible with a,
wide-range of heater control methods S87A-11N
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance OMRON S87A-11N.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Control power supply voltage: 100/110 VDC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input OMRON S87A-11N.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter OMRON Power failure detector.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T) OMRON Power failure detector.
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Input / output: 40.
Pole number: 40 OMRON Power failure detector.
I/O: input and output.
Common mode terminal: NO.
Connector mounting type: XG4A-4031.
Cable connector type: XG4M-4030-T.
The use of non threaded terminals can greatly reduce the amount of plant wiring and the required hours.
The caliper terminal so that you can no longer without fastening screws.
Only insert the rod - shaped terminal to complete a touch type wiring. Power rating: 50 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 48 V VDC.
Output current: 1.1 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-yeaar warranty S87A-11N.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved foor UL (all models) and CCC (15 to 150-W models) OMRON S87A-11N.
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.


...More relevant models >>>>