Power ratings: 180 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 7.5 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
indication monitor.
Status displayed on 3-digit, 7-segment display.
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 5V.
Output current: 3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function OMRON S8VS-18024AP.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity
S8VS-18024AP
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock OMRON S8VS-18024AP.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Category: incidental cover type OMRON S8VS-18024AP.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 1500W.
Output voltage: 24V.
Output current: 65A (AC100V) 70A (AC200V) peak current 105A (AC200V).
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON Switch Mode Power Supply.
Built in support for determining the abnormal causes of the new under voltage detection function OMRON Switch Mode Power Supply.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free OMRON Switch Mode Power Supply.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Supporrt finger touch protection to prevent electric shock S8VS-18024AP.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer OMRON S8VS-18024AP. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"