I/O classification: Input and output.
Internal I/O circuit common: PNP (input: – common; output: + common).
I/O points: 32.
I/O connection method: MIL connector.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors.
Compact dimensions: 35 × 60 × 80 (W × D × H).
Long-distance and high-speed communications modes available.
Downsizing enabled with 32-point MIL connector for I/O connection.
Specifications: Outputs;
NPN (- common);
16 points.
I/O connections: MIL connector(Connector with 10-cm cable).
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e OMRON SRT2-MD32ML-1. g., D-Sub) to,
connect to a wide range of interfaces
SRT2-MD32ML-1
35 x 60 x 80 mm (W x D x H). I/O classification: Input.
Internal I/O circuit common: PNP (– common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals OMRON SRT2-MD32ML-1.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported. Name: e-CON Connector Type.
Specifications: Analog outputs;
2 outputs.
Standards: CE, UC, UC1 OMRON SRT2-MD32ML-1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON Transistor Remote I/O Terminals with Connectors.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON Transistor Remote I/O Terminals with Connectors. Specifications: Outputs;
NPN (- common); 32 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC OMRON Transistor Remote I/O Terminals with Connectors.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H). Name: MIL Connectors.
Specifications: Inputs;
32 inputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost caan be reduced SRT2-MD32ML-1.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee OMRON SRT2-MD32ML-1.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.