Mounting method: Embedded with no screw threads.
Pin shape: Solder cup pin.
Applicable wire diameter: AWG22 to 28.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
94V-0 fire retardant rating.
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON XS2M-A422.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
XS2M-A422
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON XS2M-A422. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Specifications: For RS-232C port.
Type: RJ45/Dsub9Pin.
Length: 2 m.
Compact DC-DC UPS with a DIN rail for,
mounting, best suited for prevention of,
voltage drop and power failure in,
industrial-purpose computers OMRON XS2M-A422.
(IPC)/controllers.
System reliability greatly improved because.
24VDC power supply is backed up for a certain.
period of time in the event of voltage drop or power failure.
Compactness, weight reduction, and long battery life,
realized thanks to the adoption of a lithium-ion battery OMRON Round Water-resistant Connectors.
Push-in terminal block adopted for the power input and,
output I/F OMRON Round Water-resistant Connectors.
Shutdown in conjunction with the industrial,
purpose computer (IPC) or controller realized,
by the USB/RS-232C/I/O port installed in the UPS. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual OMRON Round Water-resistant Connectors.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indiccated from the start of operation XS2M-A422.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON XS2M-A422. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.