Type: Normal wiring.
Cable length L: 2.0 m.
Controllers with one touch.
Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.120 A; 60 Hz, 0.100 A .
Rated input: 50 Hz, 10 W ; 60 Hz, 9 W .
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 0 OMRON XW2Z-200BU. 9 m3/min.
Maximum static pressure: 50 Hz, 42.1 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB
XW2Z-200BU
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON XW2Z-200BU.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Power ratings: 15 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3) OMRON XW2Z-200BU.
Output voltage: 24 V.
Output current: 0.65 A.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards OMRON Connecting Cables for Connector-Terminal Block Conversion Units.
New models with screwless terminal blocks and,
indication monitor OMRON Connecting Cables for Connector-Terminal Block Conversion Units.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards OMRON Connecting Cables for Connector-Terminal Block Conversion Units. ) Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages and undervoltages for tthree-phase,
3-wire or 4-wire power supplies XW2Z-200BU.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire,
power supply.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and,
undeervoltages OMRON XW2Z-200BU.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator.