Item: Data Logger.
with Internal 4 GB Flash Memory.
Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2300 r/min; 60 Hz, 2600 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 41 Pa; 60 Hz, 45 Pa.
Noise: 50 Hz, 41 dB; 60 Hz, 44 dB OMRON ZR-RX45A-CHRO.
Weight: Approx. 1150 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
ZR-RX45A-CHRO
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment OMRON ZR-RX45A-CHRO.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/RJ45).
Cable length: 3 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Cable specifications: Fire-retardant, Robot cable OMRON ZR-RX45A-CHRO.
Cable length L: 1 m.
Cable outer diameter: 6 mm.
Straight/straight.
Minimum order: 10.
UL: Yes.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors OMRON Data Logger.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking OMRON Data Logger.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) OMRON Data Logger.
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phasse control, and cyclic control ZR-RX45A-CHRO.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads OMRON ZR-RX45A-CHRO.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).