LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> A0J2HCPU Programming Manual MITSUBISHI A0J2HCPU Fundamentals Manual

A0J2HCPU Programming Manual MITSUBISHI A0J2HCPU Fundamentals Manual

Product model: A0J2HCPU
Name: PLC
Brand: MITSUBISHI
Sort: Fundamentals Programming Manual
File language: English
File size: 8.33MB
NSD servo system.
A73CPU (P21/R21) -S3 dedicated.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage MITSUBISHI A0J2HCPU Manual .
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load A0J2HCPU
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program MITSUBISHI A0J2HCPU Manual .
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest MITSUBISHI A0J2HCPU Manual .
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. RS422 interface conversion cable packageInput type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0.5A.
External connecttion: 1 line /1 line type A0J2HCPU Programming Manual.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A0J2HCPU Programming Manual.
Related products
MITSUBISHI
General purpose CPU
Q06UDHCPU
MITSUBISHI General purpose CPU Q06UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Positioning module
A0J2D71
MITSUBISHI Positioning module A0J2D71
2 axes. 2 axis linear compensation. Control u
MITSUBISHI
CPU unit
A0J2HCPUP21
MITSUBISHI CPU unit A0J2HCPUP21
Input and output points: 480 points. Input /