Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc MITSUBISHI CC-Link/LT Remote I/O Module User's Manual. are connected to a simple MIL connector
CL1Y4-R1B2
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. No introductionInput voltage rating: AC100/120/230/240V
External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit MITSUBISHI CC-Link/LT Remote I/O Module User's Manual.
Dedicated power supply for CC-LINK/LT system with built-in 2A power supply. Input type: DC input, positive public end / negative public end.
Input points: 4 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A MITSUBISHI CC-Link/LT Remote I/O Module User's Manual.
External connection: 2 line /2 line type.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate CL1Y4-R1B2 User's Manual.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition CL1Y4-R1B2 User's Manual.
Can be installed along the 6 direction. Input type: DC input, positive public end / negative public end.
Input points: 4 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA.
External connection: 2 wire.
Screw terminal table type CL1Y4-R1B2 User's Manual.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. No introductionOutput type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire.
MIL connectorr type CL1Y4-R1B2 Manual.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be reeplaced with a simple module MITSUBISHI CC-Link/LT Remote I/O Module User's Manual.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space.