Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation.
Type: variable detection terminal plate / AC.
Shape: shield.
Detection range: 15mm.
Action mode: NO/NC (toggle) OMRON photoelectric sensors INSTRUCTION sheet. Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical
E3X-SD6
Connection method: Pre-wired.
Sensing distance: 100 mm (wide view).
Functions: --.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Control output 1: Voltage output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two OMRON photoelectric sensors INSTRUCTION sheet.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications OMRON photoelectric sensors INSTRUCTION sheet.
Use component communications to link Temperature,
Controllers to each other. Appearance: Close mounting.
Sensing method: Throughbeam type(with slot) E3X-SD6 INSTRUCTION sheet.
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Dark-ON/Light-ON (selectable).
Indicator mode: Incident light E3X-SD6 INSTRUCTION sheet.
Model: NPN output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity.
Series includes models that enable switching between,
dark-ON and light-ON operation.
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator E3X-SD6 INSTRUCTION sheet.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for dark-ON,
operation are also available.
A wide range of variations in eight different shapes.
Flexible robot cable is provided as a standard feature. Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: Pre-wired.
Body material: Stainless steel.
Thread length (overall length): 27 (40).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater E3X-SD6 Manual.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpiecees are eliminated OMRON photoelectric sensors INSTRUCTION sheet.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization.