Type: Shielded.
Appearance: Cylindrical, 5.4 dia. × 18 mm.
Sensing distance: 1 mm.
Repeat accuracy: 1 μm.
Cable specification: Standard.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application E3X-SD41 INSTRUCTION sheet. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads
E3X-SD41
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations E3X-SD41 INSTRUCTION sheet.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Thread length: Standard type.Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output E3X-SD41 INSTRUCTION sheet.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status off the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3X-SD41 Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3X-SD41 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.