Used to reduce radio noise.Length: 5 meters.
Operation panel or parameter unit connection line. Max input / output points: 128 points.
Power supply voltage: DC24V.
Input points: 64 points.
Output points: 64 points.
Output type: transistor.
Power consumption: 100VA.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87 MITSUBISHI FR-A740-185K-CHT TECHNICAL MANUAL.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications MITSUBISHI FR-A740-185K-CHT TECHNICAL MANUAL
FR-A740-185K-CHT
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type) MITSUBISHI FR-A740-185K-CHT TECHNICAL MANUAL.
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 315KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity. Input points: 8 points.
Output points: 6 points.
Power supply voltage: AC100-240V.
Output type: transistor output (source).
Built in CPU, power supply, input and output. Whille maintaining the convenience of FX1N while improving performance FR-A740-185K-CHT Manual .
Special adaptor and function expansion board can be installed and used FX3 series.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Applicatioon instruction: 0 FR-A740-185K-CHT Manual . 5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.