LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A2NCPU-S1 Common Instructions Programming Manual

MITSUBISHI A2NCPU-S1 Common Instructions Programming Manual

Product model: A2NCPU-S1
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
File size: 3.29MB
Points: 32 points
.
Rated voltage: DC24V.
Connection type: connector
.
Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to those who require only the ON/OFF control function of the field components, such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data A2NCPU-S1 Common Instructions.
Remote components: refers to those that require processing of the register data of the field components, such as analog I/O and counters, etc A2NCPU-S1.
In this type of component, in addition to the bit data can be carried out in the register data communication.
Intelligent remote: this type of component is to allow the main station or other stations to access the action, to collect data and control the local PLC station,
GOTS and programmer interface unit are of this type A2NCPU-S1 Common Instructions. Output points: 24 points.
Output voltage and current: AC100 ~ 240V, 0.6A/1 point, 2.4A/1 public end.
Response time: 0.5Hz+1ms.
Output form: bidirectional thyristor output.
8 point /1 a public side.
36 point terminal station.
Number of stations: 4 stops.
Compact remote I/O unit A2NCPU-S1 Common Instructions.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module haas the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system A2NCPU-S1 Programming Manual .
At the same time, tthe use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information A2NCPU-S1 Programming Manual .
Related products
MITSUBISHI
CPU unit
Q2ACPU-S1
MITSUBISHI CPU unit Q2ACPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
Motion controller
Q170MSCPU-S1
MITSUBISHI Motion controller Q170MSCPU-S1
Control axis: up to 16 axes. Interpolation fu
MITSUBISHI
CPU unit
A2SCPU-S1
MITSUBISHI CPU unit A2SCPU-S1
Program memory capacity 14K. Input and output
MITSUBISHI
CPU component
A2SHCPU-S1
MITSUBISHI CPU component A2SHCPU-S1
I/O control method: refresh mode or direct mo