MITSUBISHI CL1PSU-2A Manual CL1PSU-2A User's Manual

Product model: CL1PSU-2A
Name: CC-Link/LT Dedicated Power Supply
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.37MB
Support Ver.2 CC-LINK. "Input type: DC input, positive public end / negative public end.
Input points: 4 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No CL1PSU-2A User's Manual.
Rated load voltage / current: DC12V/DC24V/0 CL1PSU-2A1A.
External connection: 2 line /2 line type.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition CL1PSU-2A User's Manual.
Can be installed along the 6 direction. Input type: DC input, positive common end.
Input points: 1 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 1 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.1A.
External connection: 3 line /2 line type CL1PSU-2A User's Manual.
Cable type.
Minimum size of industry.
Can be like a cable, placed in the online slot.
The communication cable and the external equipment connecting cable is a type, and the wiring is simple.
Communication side, input and output side with cable (50cm). Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Output type: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load volttage / current: DC30V/AC250V/2A CL1PSU-2A Manual.
External connection: 2 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole CL1PSU-2A Manual.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.