LK Automation Limited
Home >> Products >> MITSUBISHI >> CC-Link module >> CC-link spare parts >> CL1PAD1 MITSUBISHI CL1PAD1 External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit 

CL1PAD1 MITSUBISHI CL1PAD1 External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit 

Brand: MITSUBISHI
Name: The power adapter
Model: CL1PAD1
Voltage input range: due to different connection models, the maximum DC28.8V.
External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit.
When power supply from the external power supply (customer owned) to the CC-LINK/LT system, the whole system can be stable power supply.

Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 2~4 line type.
Waterproof connector type.
Strong waterproof type of IP67 protection grade.
No need to stop the system can be replaced module MITSUBISHI CL1PAD1.
Without the use of tools can be a simple connection, save time CL1PAD1
Terminal resistor built-in.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness MITSUBISHI CL1PAD1.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Input type: DC input, positive public end / negative public end.
Input points: 8 points MITSUBISHI CL1PAD1.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup MITSUBISHI The power adapter.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool MITSUBISHI The power adapter. Screw, 2 piece type terminal.
Current output module.
Number of channels: 4 channels.
Number of stations: 2 stops.
Station type: remote equipment station.
High speed data transfer of up to 10Mbps;
The development of CC-LINK is not only to meet the control of high speed remote I/O,
But also to meet the high speed of the field of information control MITSUBISHI The power adapter.
In order to achieve this goal, the transmission speed of CC-LINK is compared with that of the previous live network system to add 40 to 10Mbps.
Such a high speed can not affect the speed of the machine control while allowing a large number of data communication. Pulse input: differential input.
Default input: DC input.
Count range: 0~16777215.
Number of stations: 4 stops.
Station type: remote equipment station.
Configuration of master / local station,
In addition to the other site network with different CC-Link in addition to the main station and the remote station configuration can also be the main station and the local station configuration.
A local PLC can communicate with the master station PLC and other remote workstations.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-lline unification to adjust CL1PAD1.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on stepp by step MITSUBISHI CL1PAD1.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.


...More relevant models >>>>