Product model: FR-A740-90K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: Applied INSTRUCTION MANUAL
File language: English
File size: 15.98MB
Power: 45kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor FR-A740-90K-CHT INSTRUCTION MANUAL. (the IP55 series has a built-in DC reactor FR-A740-90K-CHT)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Series Name: F920GOT with buttons, with a series of effective functional modules.
System screen display language: english.
Display: 2.6 inches FR-A740-90K-CHT INSTRUCTION MANUAL.
Display color: monochrome (blue / white).
Display device: LCD STN.
Resolution: 128 * 64.
Installation type: panel mounting.
The built-in communication port: RS-422 (1ch) /RS-232C (1ch).
Power supply voltage: DC5V.
The touch screen is the interface between people and machines in the field of information exchange and function contact or interact with each other,
Information exchange, functional contact or mutual influence, the hard contact and soft touch of a person and machine,
This interface includes not only the direct contact point, including long-distance information transmission and control function space FR-A740-90K-CHT INSTRUCTION MANUAL.
The man-machine interface is the central link in the man-machine system,
Mainly from the safety engineering branch of the safety ergonomics to study and put forward the basis for the solution,
And over safety engineering equipment engineering,
Safety management engineering and safety systems engineering to study the specific solutions and measures of the safety of human computer science. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 45kw.
SLD converter rated current: 93A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor FR-A740-90K-CHT Manual.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FR-A740-90K-CHT Manual.
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-220K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-220K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-22K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-22K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-2.2K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-2.2K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-11K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-11K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l