"Power: 55kw.
Voltage: 400V.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor.
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit MITSUBISHI FR-A740-18.5K-CHT Manual.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time consumed and the DC part "overpressure",
Need to add external braking components, in order to speed up the speed of the consumption of renewable energy FR-A740-18.5K-CHT "Max input / output points: 80 points.
Supply voltage: 100 - 240VAC.
Input points: 40 points MITSUBISHI FR-A740-18.5K-CHT Manual.
Output points: 40 points.
Output type: relay.
Power consumption: 70VA.
Weight (kg):1.2.
Size (WxHxD) mm:285x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications MITSUBISHI FR-A740-18.5K-CHT Manual.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. Input and output points: 40 points.
Power supply: DC24V.
Input points: 24 points.
Output points: 16 points.
Output form: transistor output (drain).
Power consumption: 25W.
Weight: 0.7KG.
Outline dimension: 130x90x86mm.
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Appplication instruction: 0 FR-A740-18.5K-CHT INSTRUCTION MANUAL. 5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.
Third generation standard model.
Easy to use integraated models and flexible scalability FR-A740-18.5K-CHT INSTRUCTION MANUAL.
Condensed convenience of using the usual FX3 series.
Its high price by the most suitable for small scale control.
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-0.75K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-0.75K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-110K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-110K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-280K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-280K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-7.5K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-7.5K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l