"Power: 15kw.
Voltage: 400V.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor.
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit FR-E540-3.7K-CH Manual.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time consumed and the DC part "overpressure",
Need to add external braking components, in order to speed up the speed of the consumption of renewable energy
FR-E540-3.7K-CH "Function: no terminal input.
Input points: 16 points.
Connected programmable logic controller: FX1NC, FX2NC, FX3UC FR-E540-3.7K-CH Manual.
Weight: 0.15KG.
FX2NC expansion module can be directly connected to the FX1NC, FX2NC, PLC FX3UC on the expansion of the input and output.
Do not need to connect the cable and so on, therefore can carry on the compact expansion. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 110KW.
Frequency converter common frequency of a given way: the operator keyboard is given, the contact signal given, analog signal given, the pulse signal given and communication methods given, etc FR-E540-3.7K-CH Manual. .
These frequencies have their advantages and disadvantages, and should be selected according to the actual needs MITSUBISHI TRANSISTORIZED INVERTER Manual.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions MITSUBISHI TRANSISTORIZED INVERTER Manual. Length: 5 meters.
Cable manufacturing specifications MITSUBISHI TRANSISTORIZED INVERTER Manual.
When there is no connection options, according to the table under the cable.
Using a parallel connection or a large size cable for connection between the terminal PG" and "SD" and the motor end encoder. "Input / output type: DC input (drain / source).
Input and output points: 8 points.
DC5V internal consumption currrent: 75mA FR-E540-3.7K-CH TECHNICAL MANUAL.
DC24V internal consumption current: 50mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion modulee: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FR-E540-3.7K-CH Manual.