Analog input: 2.
Analog output points: 1 points.
Weight: 0.1kg.
FX3 series can be connected to the 2 channel input (voltage: DC0~10V, or current DC4~20mA), as well as 1 channel output (DC0~10V, or current: DC4~20mA) of the adapter.
Each channel can be specified as a current input or voltage input.
Connecting FX3SA, FX3S, FX3GA, FX3G, and FX3U main body, the need to convert the adapter or function expansion board FX2N-232IF Manual
FX2N-232IF Max input / output points: 14 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 6 points.
Output type: relay.
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types FX2N-232IF Manual.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FX2N-232IF Manual.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 3.7kw.
SLD converter rated current: 8 MITSUBISHI RS-232C Interface Module Manual. 3A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed MITSUBISHI RS-232C Interface Module Manual.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor MITSUBISHI RS-232C Interface Module Manual.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Max input / output points: 48 points.
Power supply voltage: 24VDC.
Input points: 24 points.
Output points: 24 points.
Output type: Transistor (source).
Power consumption: 30W.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protectionn, using a eight digit password to protect your program FX2N-232IF USER'S MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FX2N-232IF Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).