LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L06CPU-P PROGRAMMING Guide Book L06CPU-P Structured Text(ST) Manual

MITSUBISHI L06CPU-P PROGRAMMING Guide Book L06CPU-P Structured Text(ST) Manual

Product model: L06CPU-P
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) PROGRAMMING Guide Book
File language: English
File size: 2.99MB
Output points: 16 points.
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called L06CPU-P PROGRAMMING Guide Book L06CPU-P
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol L06CPU-P PROGRAMMING Guide Book. Output points: 16 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called L06CPU-P PROGRAMMING Guide Book.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Differential output.
Axis of control: 4.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH,, bit 8CH data can be displayed in real time L06CPU-P Manual .
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display L06CPU-P Manual .
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.
Related products
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type. Prog