LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q06HCPU-A Strctured Programming Manual CPU Application Functions Manual

MITSUBISHI Q06HCPU-A Strctured Programming Manual CPU Application Functions Manual

Product model: Q06HCPU-A
Name: CPU
Brand: MITSUBISHI
Sort: Application Functions Strctured Programming Manual
File language: English
File size: 5.50MB
"1 axes, SSCNET III type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
40 pin connector.
Through the SSCNET III cable connection to save wiring, the distance between the station up to 50m.
Absolute position system for determining the origin position is supported by the return data set operation Q06HCPU-A Manual.
In addition, the limit switch of the upper limit, the lower limit switch and the near point block signal input can be directly connected to the servo amplifier,
Thus greatly reducing the wiring requirements Q06HCPU-A
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc Q06HCPU-A Manual. .
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug. "Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module Q06HCPU-A Manual.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling MITSUBISHI CPU Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode MITSUBISHI CPU Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost MITSUBISHI CPU Manual.
Heating function at the ssame time Q06HCPU-A Strctured Programming Manual.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q06HCPU-A Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
High performance CPU
Q06HCPU
MITSUBISHI High performance CPU Q06HCPU
Program capacity: 60 K step. Input / output p
MITSUBISHI
A mode Q series CPU
Q06HCPU-A
MITSUBISHI A mode Q series CPU Q06HCPU-A
Input / output points: 4096 points. Numer of
MITSUBISHI
A mode Q series CPU
Q02CPU-A
MITSUBISHI A mode Q series CPU Q02CPU-A
Input / output points: 4096 points. Numer of
MITSUBISHI
A mode Q series CPU
Q02HCPU-A
MITSUBISHI A mode Q series CPU Q02HCPU-A
Input / output points: 4096 points. Numer of