Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 26 K step.
Processing speed: 79ns.
Program memory capacity: 144 KB.
Built in RS232 communication port.
Support installed memory card.
For A mode only.
Enhance the basic performance.
CPU''s built-in soft element memory capacity increases to up to 60K.
To increase the control, quality management data can also be processed at high speed.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
Capacity up to 4736K words, thus simplifying the programming.
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording MITSUBISHI Q02CPU-A
Q02CPU-A
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance MITSUBISHI Q02CPU-A.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.Redundant CPU data tracking cable length of 1 meters.
Can only be used for MITSUBISHI Q series PLC redundancy CPU MITSUBISHI Q02CPU-A. ABS serial synchronous encoder input can be used: 2 sets of modules / units.
Position detection method: compiled on value (ABS) method.
Transmission mode: serial communication.
Allows you to track target input points: 2.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server MITSUBISHI A mode Q series CPU MITSUBISHI A mode Q series CPU.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution MITSUBISHI A mode Q series CPU. Input points: 16 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
16 point /1 a public side.
Common cathode.
18 point terminal station.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of tyypes of I/O, analog and positioning function module Q02CPU-A.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of thhe positioning of the industry, the control needs of various fields MITSUBISHI Q02CPU-A.
Can also be used in combination with the CPU module to achieve appropriate control.