LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q06UDHCPU Programming Guide Book MITSUBISHI Q06UDHCPU Structured Text(ST) Manual Q06UDHCPU

MITSUBISHI Q06UDHCPU Programming Guide Book MITSUBISHI Q06UDHCPU Structured Text(ST) Manual Q06UDHCPU

Product model: Q06UDHCPU
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) Programming Guide Book
File language: English
File size: 1.23MB
Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost MITSUBISHI Q06UDHCPU Manual.
Heating function at the same time Q06UDHCPU
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced MITSUBISHI Q06UDHCPU Manual.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode MITSUBISHI Q06UDHCPU Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected. PCI bus /PCI-X bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit largee number of bits data (such as ON/OFF information) and word data (such as analog information) Q06UDHCPU Programming Guide Book.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q06UDHCPU Programming Guide Book.
Even if the information reaches saturation, it will not affect the link scan time.
Related products
MITSUBISHI
General purpose CPU
Q13UDHCPU
MITSUBISHI General purpose CPU Q13UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q50UDEHCPU
MITSUBISHI With Ethernet CPU Q50UDEHCPU
Input / output points: 4096 points. Numer of