C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01.Product name: CS1 CPU Backplane.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 8 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No CJ2H-CPU65 Safety Precautions.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No
CJ2H-CPU65
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. 1 axis, Pulse input. counting speed: 50 kcps CJ2H-CPU65 Safety Precautions. 5VDC/12 VDC/24 VDC.CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP227.
8-MB memory; w/floating-point processor.CV500-CN Cable Bus Connecting Cable Used to join two Hard Disk Units CV500-CN116.C500-OC I/O Unit Transistor Output 32 pts C500-OC224-E(3G2A5-OC224-E).
AC250/DC24V 2A.Model: C200H-OD501.
No. of outputs: 32 pts.
Specifications: 5VDC.4 platinum resistance thermometer inputsProduct name: DC Power Supply Unit CJ2H-CPU65 Safety Precautions.
Power supply voltage: 24 VDC. 5A;
24-VDC output capacity, 0.8A;
Total power consumption, 25w.
Options: 24-VDC service power supply, No;
RUN output, No; Maintenance forecast monitor, No.
Standards: UC1, N, L, CE.
Equipped with the RUN output for,
checking the operation status,
as well as the replacement.
notification function for easy,
maintenance.
Lineup of five models including the,
AC power supply (25W).
Stable power supply is available from the,
CJ-series CPU Unit to each I/O Units via the,
dedicated bus. The most suitable Power Supply,
Unit can be selected among various I/O ,
specifications and/or options. Name: Analog I/O Slave Units,
(Numerical indicator type)
e-CON Connector Type.
Specifications: Analog inputs.
(Channel Insulation); 2 inputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ2H-CPU65 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ2H-CPU65 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.