LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON E3Z-LR61-M1J INSTRUCTION sheet E3Z-LR61-M1J Manual

OMRON E3Z-LR61-M1J INSTRUCTION sheet E3Z-LR61-M1J Manual

Product model: E3Z-LR61-M1J
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.96MB
Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, None;
Material, --;
Count, -- .
Applicable sensor (mounting pitch on sensor side): E3X-DA-S/MDA,
E3X-NA, E3C-LDA, E2C-EDA, E4C-UDA.
Page: Dimensions, 13. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V) E3Z-LR61-M1J INSTRUCTION sheet.
Shell color: black.
Control output: voltage output (SSR driver) E3Z-LR61-M1J
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products E3Z-LR61-M1J INSTRUCTION sheet.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E3Z-LR61-M1J INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultSize: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check thhe state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3Z-LR61-M1J Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E3Z-LR61-M1J Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Compact Laser Photoelectric Sensor
E3Z-LR81
OMRON Compact Laser Photoelectric Sensor  E3Z-LR81
Sensing method: Retro-reflective with MSR fun
OMRON
Compact Laser Photoelectric Sensor
E3Z-LR66
OMRON Compact Laser Photoelectric Sensor  E3Z-LR66
Sensing method: Retro-reflective with MSR fun
OMRON
Compact Laser Photoelectric Sensor
E3Z-LR86
OMRON Compact Laser Photoelectric Sensor  E3Z-LR86
Sensing method: Retro-reflective with MSR fun