LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> photoelectric sensors E3Z-LR61 Manual OMRON E3Z-LR61 INSTRUCTION sheet

photoelectric sensors E3Z-LR61 Manual OMRON E3Z-LR61 INSTRUCTION sheet

Product model: E3Z-LR61
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.96MB
Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: - E3Z-LR61 Manual.
Communication: -.
Event input: -.
Remote SP input: -.
Transfer output: - E3Z-LR61
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports E3Z-LR61 Manual.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E3Z-LR61 Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication OMRON E3Z-LR61 INSTRUCTION sheet.
A new type of proportional control allows you to control the valve. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON E3Z-LR61 INSTRUCTION sheet.
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: transfer output (special terminal) OMRON E3Z-LR61 INSTRUCTION sheet.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E3Z-LR61 .
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
Related products
OMRON
Narrow-beam Photoelectric Sensor
E3Z-L66
OMRON Narrow-beam Photoelectric Sensor  E3Z-L66
Sensing method: Narrow-eam reflective. Conn
OMRON
Compact Photoelectric Sensor
E3Z-R81
OMRON Compact Photoelectric Sensor E3Z-R81
Sensing method: Retro-reflective with MSR fun
OMRON
Compact Photoelectric Sensor
E3Z-T86
OMRON Compact Photoelectric Sensor E3Z-T86
Sensing method: Through-eam Emitter Recei