Name: Clamp Terminal Blocks.
Specifications: Outputs; 16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CS1D-CPU67H-IAP Manual.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
CS1D-CPU67H-IAP
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. UM: 3.2K words.
DM: 4K words.
EM: --.
Instruction processing time (basic instructions): 0.3 µ.s min CS1D-CPU67H-IAP Manual.
No. of I/O points: 640 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model: CPM2C-8ETM. Units with relay outputs only.
1 MIL connector.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Unit classifi cation: CS1 CPU Bus Unit CS1D-CPU67H-IAP Manual.
Product name:Controller Link Unit.
Specifications: Communications cable,
Wired shielded twisted-pair cable;
Communications type, Data links and,
message service; Duplex support, No.
Max. Units mountable per CPU Unit, 8.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 OMRON CS1D-CPU67H-IAP REFERENCE MANUAL. 33A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed OMRON CS1D-CPU67H-IAP REFERENCE MANUAL.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required OMRON CS1D-CPU67H-IAP REFERENCE MANUAL.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Name: Two-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can bbe reduced CS1D-CPU67H-IAP Communications Commands.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1D-CPU67H-IAP Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.