LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> PLC L02CPU-CM Structured Text Programming Manual MITSUBISHI L02CPU-CM Manual

PLC L02CPU-CM Structured Text Programming Manual MITSUBISHI L02CPU-CM Manual

Product model: L02CPU-CM
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
File size: 4.20MB
IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module L02CPU-CM Programming Manual.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space L02CPU-CM
Management of abnormal information through the RAS function
An error occurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network L02CPU-CM Programming Manual.
Even if the power of the system is cut off, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime. AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units L02CPU-CM Programming Manual.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points MITSUBISHI L02CPU-CM Manual .
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor MITSUBISHI L02CPU-CM Manual .
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module MITSUBISHI L02CPU-CM Manual .
In addition to the 2 wire type, the local power supplly can be connected with the 4 wire type mixed use L02CPU-CM Structured Text.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power suupply L02CPU-CM Programming Manual.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load.
Related products
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type. Prog